Home>>Product

FWI-CKI3 Three phase 380v Input AC Choke(reactor)

 

Functions:
1.Reduction of harmonics , Improvement of the power factor
2.Over-voltage restriction
3.Reducing the stress caused by noise to motor, extended the life span of motor
4.Improvement of low-frequency conduction emission/sensitivity

 

Technical specifications:
1.Rated Voltage: 440VAC
2.Hipot test voltage
3.Operating Frequency: 50/60 Hz
4.Insulation class: H
5.Rated Current: 3A ~ 800 A
6.Altitude: <100 0 meters
7.Ambient temperature: -25℃~ 40℃
8.Reactor impedance: 2%
9.Protection category: IP00

 

FWI-CKI3 Three phase 380v Input AC Choke (reactor)

Model No.

Voltage

Power

Current

G.W

Packing size

Installation dimension

Picture

(V)

(KW)

(A)

(KG)

L/W/H(mm)

H/W/D(mm)

FWI-CKI3-d75

400

0.75

1.8A

2

120/76/110

70/47/Ф7

FWI-CKI3-1d5

400

1.5

2.5A

2.2

120/76/110

70/47/Ф7

FWI-CKI3-2d2

400

2.2

5A

3

120/92/120

70/47/Ф7

FWI-CKI3-004

400

4

10A

4

130/80/138

75/60/Ф7

FWI-CKI3-5d5

400

5.5

15A

4.5

130/80/138

75/68/Ф7

FWI-CKI3-7d5

400

7.5

20A

5

160/100/160

90/65/Ф7

FWI-CKI3-011

400

11

30A

6

160/120/165

90/78/Ф7

FWI-CKI3-015

400

15

30A

6

160/120/165

90/78/Ф7

FWI-CKI3-018

400

18

50A

9

205/125/160

110/70/Ф7

FWI-CKI3-022

400

22

50A

9

205/125/160

110/70/Ф7

FWI-CKI3-030

400

30

60A

10

205/130/146

110/83/Ф7

FWI-CKI3-037

400

37

75A

11

205/135/163

110/88/Ф7

FWI-CKI3-045

400

45

90A

12

205/140/164

110/88/Ф7

FWI-CKI3-055

400

55

120A

16

225/165/192

120/100/Ф10

FWI-CKI3-075

400

75

150A

19

225/176/203

120/110/Ф10

FWI-CKI3-090

400

90

190A

23

280/196/214

150/110/Ф10

FWI-CKI3-110

400

110

210A

26

280/205/216

150/110/Ф10

FWI-CKI3-125

400

125

250A

28

280/216/212

150/121/Ф10

FWI-CKI3-132

400

132

290A

30

280/217/235

150/121/Ф10

FWI-CKI3-160

400

160

330A

32

280/205/234

150/121/Ф10

FWI-CKI3-185

400

185

400A

38

320/210/270

160/130/Ф10

FWI-CKI3-220

400

220

440A

45

320/210/270

160/130/Ф10

FWI-CKI3-250

400

250

490A

50

320/230/270

160/140/Ф10

FWI-CKI3-280

400

280

540A

53

320/230/290

160/140/Ф10

FWI-CKI3-315

400

315

600A

63

390/240/335

200/130/Ф10

FWI-CKI3-350

400

350

700A

68

390/245/350

200/130/Ф13

FWI-CKI3-400

400

400

800A

78

390/265/330

200/150/Ф13

FWI-CKI3-500

400

500

1000A

90

435/290/365

240/162/Ф14

FWI-CKI3-560

400

560

1100A

100

435/290/385

240/162/Ф14

FWI-CKI3-600

400

600

1250A

110

435/317/363

240/187/Ф14


FWI-CKO3 Three phase 380v Output AC Choke (reactor)

Model No.

Voltage

Power

Current

G.W

Packing size

Installation dimension

Picture

(V)

(KW)

(A)

(KG)

L/W/H(mm)

H/W/D(mm)

FWI-CKO3-d75

400

0.75

1.8A

2

120/76/110

70/47/Ф7

FWI-CKO3-1d5

400

1.5

2.5A

2.2

120/76/110

70/47/Ф7

FWI-CKO3-2d2

400

2.2

5A

3

120/92/120

70/47/Ф7

FWI-CKO3-004

400

4

10A

4

130/80/138

75/60/Ф7

FWI-CKO3-5d5

400

5.5

15A

4.5

130/80/138

75/68/Ф7

FWI-CKO3-7d5

400

7.5

20A

5

160/100/160

90/65/Ф7

FWI-CKO3-011

400

11

30A

6

160/120/165

90/78/Ф7

FWI-CKO3-015

400

15

30A

6

160/120/165

90/78/Ф7

FWI-CKO3-018

400

18

50A

9

205/125/160

110/70/Ф7

FWI-CKO3-022

400

22

50A

9

205/125/160

110/70/Ф7

FWI-CKO3-030

400

30

60A

10

205/130/146

110/83/Ф7

FWI-CKO3-037

400

37

75A

11

205/135/163

110/88/Ф7

FWI-CKO3-045

400

45

90A

12

205/140/164

110/88/Ф7

FWI-CKO3-055

400

55

120A

16

225/165/192

120/100/Ф10

FWI-CKO3-075

400

75

150A

19

225/176/203

120/110/Ф10

FWI-CKO3-090

400

90

190A

23

280/196/214

150/110/Ф10

FWI-CKO3-110

400

110

210A

26

280/205/216

150/110/Ф10

FWI-CKO3-125

400

125

250A

28

280/216/212

150/121/Ф10

FWI-CKO3-132

400

132

290A

30

280/217/235

150/121/Ф10

FWI-CKO3-160

400

160

330A

32

280/205/234

150/121/Ф10

FWI-CKO3-185

400

185

400A

38

320/210/270

160/130/Ф10

FWI-CKO3-220

400

220

440A

45

320/210/270

160/130/Ф10

FWI-CKO3-250

400

250

490A

50

320/230/270

160/140/Ф10

FWI-CKO3-280

400

280

540A

53

320/230/290

160/140/Ф10

FWI-CKO3-315

400

315

600A

63

390/240/335

200/130/Ф10

FWI-CKO3-350

400

350

700A

68

390/245/350

200/130/Ф13

FWI-CKO3-400

400

400

800A

78

390/265/330

200/150/Ф13

FWI-CKO3-500

400

500

1000A

90

435/290/365

240/162/Ф14

FWI-CKO3-560

400

560

1100A

100

435/290/385

240/162/Ф14

FWI-CKO3-600

400

600

1250A

110

435/317/363

240/187/Ф14


FWI-DCR3 Single-phase 700v DC Choke (reactor)

Model No.

Voltage

Power

Current

G.W 

Packing size

Installation dimension

Picture

(V)

(KW)

(A)

(KG)

L/W/H(mm)

H/W/D(mm)

FWI-DCR3-D40 

700

0.4

1.5

1.8 

78/65/85

56/45

FWI-DCR3-D55

700

0.55

2

1.8 

78/65/85

56/45

FWI-DCR3-D75

700

0.75

2.5

1.8 

78/65/85

56/45

FWI-DCR3-1D5

700

1.5

4.5

2.3 

78/80/85

56/59

FWI-DCR3-2D2

700

2.2

6

2.6 

84/95/93

64/58

FWI-DCR3-3D0

700

3

8

2.8 

84/110/93

64/58

FWI-DCR3-3D7

700

3.7

11

3.1 

96/110/105

84/67

FWI-DCR3-5D5

700

5.5

16

3.4 

96/135/105

84/67

FWI-DCR3-7D5

700

7.5

20

3.4 

120/105/126

90/73

FWI-DCR3-011

700

11

30

4.8 

120/115/130

90/78

FWI-DCR3-015

700

15

35

5.8 

120/125/130

90/88

FWI-DCR3-18D5

700

18.5

42

6.4 

120/130/135

90/88

FWI-DCR3-022

700

22

50

7.5 

120/135/135

90/93

FWI-DCR3-030

700

30

68

8.5 

150/145/140

122/78

FWI-DCR3-037

700

37

80

8.5 

150/155/140

122/88

FWI-DCR3-045

700

45

100

11.6 

150/175/140

122/98

FWI-DCR3-055

700

55

120

13.7 

150/180/140

122/103

FWI-DCR3-075

700

75

165

17.8 

150/164/215

110/93

FWI-DCR3-090

700

90

190

20.8 

150/180/215

110/107

FWI-DCR3-110

700

110

250

22.1 

175/190/215

120/110

FWI-DCR3-132

700

132

300

24.5 

175/205/215

120/124

FWI-DCR3-160

700

160

350

24.9 

175/215/215

120/124

FWI-DCR3-185

700

185

400

28.8 

200/212/280

150/115

FWI-DCR3-200

700

200

440

36.1 

200/220/280

150/120

FWI-DCR3-220

700

220

480

38.2 

200/225/280

150/125

FWI-DCR3-250

700

250

550

40.5 

200/240/280

150/145

FWI-DCR3-280

700

280

600

46.3 

250/242/310

180/142

FWI-DCR3-300

700

300

650

48.7 

250/245/310

180/142

FWI-DCR3-315

700

315

700

56.1 

250/250/310

180/142

FWI-DCR3-355

700

355

800

60.2 

250/260/328

180/152

FWI-DCR3-400

700

400

900

66.6 

250/260/328

180/152

FWI-DCR3-450

700

450

1000

69.2 

250/290/314

180/182

FWI-DCR3-500

700

500

1100

77.2 

250/310/330

180/182

FWI-DCR3-560

700

560

1250

85.3 

250/310/370

180/182

 

 

Application:

Knitting Machine, compressor, extruding  machine, injection machine, motor, braiding machine, pressure fan, forced  draught blower, blower, blowing machine, blow molding machine, root's blower,  film blowing machine, cutter bar, cut-off machine, slitter, Cutting machine,  conveyor, pump, grinder, cluster, glazing machine, polisher, polishing machine,  laundry-drier, drying machine, ball crusher, ball grinding mill, drawing machine

Brosea EMI Filter & Reactor suit for Branding as follows:

ABB, SIEMENS, DANFOSS, VACON, SEW, LENZE, PETER ELECTRONIC, LEISTER, WATT DRIVE, KEB, BONFIGLIOLI, NORD, CAG ELECTRIC MACHINERY, INTECNO, SYCOTEC, KB ELECTRONICS, TDE MACNO SPA, GEFRAN, CONTROL TECHNIQUES, PEPPERL FUCHS, GRUNDFOS, VEM MOTORS, BR INDUSTRI-ELEKTRONIK, RK ROSE+KRIEGER, CARLO GAVAZZI, LEROY SOMER, VERLINDE, TRANSTECNO, STAHL CRANE SYSTEMS GMBH, MIYACHI, DEMAG CRANES COMPONENTS, ABM, ROSSI, COGNITO QUAM, GE, AIRTECNICS, Delta, Teco, Toshiba, Mitsubishi, fuji, Yaskawa, Hitachi, Omron, Panasonic, HYUNDAI, LS/LG

Main Products:

frequency inverter, AC Drives, frequency converters, frequency changers, adjustable speed drives (ASD), adjustable frequency drives (AFD), variable frequency drives (VFD), variable speed drives (VSD), Soft Starters, Soft Stop, Soft Starters for AC Motor, Motor Starters, Motor Soft Starters, EMI filter, Input EMI Filters, Output EMI Filters, AC Choke, AC Reactor, Input AC Choke, Output AC Choke, Input AC Reactor, Output AC Reactor, DC Choke, DC Reactor, Input DC Choke, Output DC Reactor, Input DC Reactor, HMI, Human Machine Interface,PLC,Programmable Logic Controller, Servo Drive, Servo Motor, Servo Motor & Drive, Servo Motor & Drive System